Dry Biochemical Analyzer
Dry Biochemical Analyzer
◆ Data transmission: it can upload data by USB, blue teeth, wifi and GPRS…
◆ Intelligentization: The machine can offer corresponding treatment advice basis on test result.
◆ Test item:
Lipid + Glucose (TC, TG, HDL-C, GLU);
Screening of Blood Donors (Hb, ALT);
Screening for Metabolic Disease (TC, UA, GLU);
Liver Function (ALB, ALT, AST);
Kidney Function (Urea, Cre, UA).
◆ Test method: Reflection spectrophotometry
◆ Sample dosage ≤ 45μL
◆ Inspection time ≤ 3min;
◆ Type of sample: peripheral blood or venous blood
◆ Display: it can display test result and historical record query
◆ Power: 5V/3A power adapter, built-in lithium battery
◆ Heating module: the equipment will design temperature in the condition of cold environment.
Data transmission | USB, blue teeth, Wifi, GPRS |
Test Item | TC, TG, HDL, LDL, Glu |
Test method | Dry chemistry |
Sample dosage | ≤ 60μl |
Inspection Time | ≤ 3min |
Type of sample | peripheral blood or venous blood |
Power | 5V/3A power adapter, built-in lithium battery |
Measurement | Lipids+Glucose TC: 2.59~12.93 mmol/L TG: 0.51~7.34 mmol/L HDL-C: 0.39~2.59 mmol/L GLU: 2.0-18.0 mmol/L |
Kidney Function Urea: 2.5~40 mmol/L Cre: 30~1000 μmol/L UA: 120~1200 μmol/L |
|
Liver Function ALB: 10~60 g/L ALT: 10~800 U/L AST: 10~800 U/L |
|
Screening for Metabolic diseases TC: 2.59~12.93 mmol/L UA: 120~1200 mmol/L GLU: 2~18 mmol/L |
|
Screening of blood donors Hb: 45~256g/L ALT: 100~800 U/L |
|
Repeatability | CV≤5% |
Accuracy | within ±10% |
1. Insert the test card into the detection slot.
2. Use a pipette to draw 45μL blood sample.
3. Add the collected blood sample to the sample hole of test card and start testing.
4. Check test results after 3 mins.
Clinics, family doctors:
For disease screening and diagnosis of patients' conditions.
Recommended test cards:
Lipids+Glucose, liver function, kidney function
Chronic disease management:
Pharmacies, chronic disease management, and health management institutions provide long-term monitoring for patients with chronic disease.
Recommended test cards:
Lipids+Glucose, screening for metabolic diseases
Bedside test:
In order to get patient testing data quickly and develop follow-up treatment plan to reduce the sudden death rate for all levels of hospitals emergency and bedside testing.
Recommended test cards:
Lipids+Glucose, liver function, kidney function
Initial screening of blood donors:
Applied in blood stations or blood donation vehicles for initial screening of blood donors.
Recommended test cards:
Screening of blood donors